Technical specifications

System:

Working Fluid Toluene
Heat Source inlet temperature > 350 ºC
Heat Source 450 - 900 kWth
Cooling Water 350 - 700 kWth
Cooling temperatures 35 -> 55 ºC
Control Advanced Computer controlled
Remote monitoring Internet TCP / IP
Operation Unmanned / remote
Package Outdoor placement IP55 / UV Protected
Standard transport dimensions


Performances:

Electrical Power 60 - 165 kWe
Electrical connection 50 Hz / 400 V / 3 ph
Emissions Zero

 

Dimensions:

  Package Control cabinet
Length 3,2 m 1,2 m
Width 2,4 m 1,6 m
Height 4 m 2,2 m
Weight 12000 kg 2000 kg


Components:

Evaporator Directly heated, no need for thermal oil system
Generator High speed asynchronous machine
Turbine Single stage 18000 - 28000 rpm
Bearing Hydro dynamically lubricated
Lubricant Toluene