Home label

BIOMASS

Group top

The Triogen ORC can be used with biomass combustion, for example sawdust, chips, bark and treated wood; and other biomasses, such as straw, rice, husks and bio-sludge, as well as other high organic-content waste. The Triogen ORC will be connected to the combustor. The Triogen ORC converts the flue gasses from the combustor into electricity.

 

Benefits

  • Enables local scale, decentralized power and heat production
  • Close to fuel source and/or heat
  • Conversion of difficult materials into revenue sources instead of costly disposal
  • Highest efficiency solution on the market in this power range
  • Compared to steam plants, ORC requires less supervision, no need for water treatment and lower maintenance costs

SOLUTION FOR HIGH-QUALITY FUELS:

DIRECT EVAPORATION

 e-box direct evaporation biomass

  • Fuel and combustion: Woods chips or other high-grade fuel is fed into a furnace, gasifier/flare (1.2 MWth per ORC)
  • Flue gas handling: The flue gas passes through a heat exchanger(“evaporator”) where it heats up the ORC working medium.
  • Power conversion: In the ORC, a turbine drives the generator producing up to 170 kW power; the ORC also provides heat in the form of cooling water. Multiple ORCs can be operated in parallel.

 

Inputs

Outputs

Fuel: 3000 - 4000t/year assuming 11 MJ/kg

Gross power ORC: up to 170 kWel

 

Net power ORC: up ot 160 kWel (after own consumption)

Plant own consumption (furnace, extraction fan, etc.) typically ~30 - 50kWel.

Cooling water with 770 kWth heat at 55-80 oC



SOLUTION FOR LOW GRADE FUELS:

INTERMEDIATE AIR LOOP

e-box intermediate air loop biomass solutions

  • Fuel and combustion: Chicken litter, manure, waste wood, RDF or other low grade fuel is fed into a burner (~1.3 – 1.6 MWth  per ORC) that produces hot flue gases
  • Flue gas handling: The flue gas passes through an air-air heat exchanger designed to handle aggressive flue gases with high ash-content. It heats up air which runs in a closed loop to a heat exchanger (“evaporator”) where it heats up the ORC working medium.
  • Power conversion: In the ORC, a turbine drives the generator producing up to 170kW power; the ORC also provides heat in the form of cooling water. Multiple ORCs can be operated in parallel

 

Inputs

Outputs

Fuel: 3000 - 4000t/year  assuming 11 MJ/kg

Gross power ORC: up to 170 kWel

 

Net power ORC: up ot 160 kWel (after own consumption)

Plant own consumption (furnace, extraction fan, air loop, etc.) typically ~50 - 70kWel.

Cooling water with 770 kWth heat at 55-80 oC

 

See for more information our Biomass Solutions Flyer